Belden 89416 Cable Equivalent, FEP-TFE, Price $950/1000 ft.
Detailed Specifications and Technical Data

Description: 16 AWG stranded (19x29) TC conductors, FEP insulation, four conductor, overall foil shield (100% coverage), 18 AWG stranded TC drain wire, FEP jacket - Red. Plenum Rated CMP.

Physical Characteristics:
BELDEN 89416 CABLE
CONDUCTOR:
PRICE $950/1000 ft.

Number of Pairs  --
Total Number of Conductors 4
AWG 16
Stranding 19x29
Conductor Material TC - Tinned Copper
BELDEN 89416 CABLE INSULATION:
Insulation Material FEP - Fluorinated Ethylene Propylene
Nom. Insulation Wall Thickness .007 in.
Lay Length  --
Twists/ft.  --
Pair Color Code Chart:
Number: 1

Black, White, Red, Green
BELDEN 89416 OVERALL CABLING:
Overall Cabling Separator Material Polyester tape
Overall Cabling Separator Thickness 0.001 in.
BELDEN 89416 CABLE OUTER SHIELD:
Outer Shield Type Tape
Outer Shield Material Aluminum Foil-Polyester Tape
Outer Shield % Coverage 100%
BELDEN 89416 CABLE OUTER SHIELD DRAIN WIRE:
Outer Shield Drain Wire AWG 18
Outer Shield Drain Wire Stranding Stranded
Outer Shield Drain Wire Conductor Material TC - Tinned Copper
BELDEN 89416 CABLE OUTER JACKET:
Outer Jacket Material FEP - Fluorinated Ethylene Propylene
Outer Jacket Nominal Wall Thickness .014 in.
BELDEN 89416 CABLE OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .190 in.
BELDEN 89416 CABLE MECHANICAL CHARACTERISTICS:
Operating Temperature Range -70°C To +200°C
Bulk Cable Weight 45 lbs/1000 ft.
Max. Recommended Pulling Tension 100 lbs.
Min. Bend Radius (Install) 2.2 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
BELDEN 89416 CABLE APPLICABLE STANDARDS:
NEC/(UL) Specification CMP
CEC/C(UL) Specification CMP
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
BELDEN 89416 CABLE FLAME TEST:
UL Flame Test NFPA 262
C(UL) Flame Test FT6
BELDEN 89416 CABLE SUITABILITY:
Suitability - Indoor Yes
Suitability - Outdoor Yes
Suitability - Burial Yes
Oil Resistance Yes
BELDEN 89416 CABLE ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance -- 
Nom. Inductance  --
Nom. Capacitance Cond. to Cond. @ 1 KHz 35 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 63 pF/ft
Nominal Velocity of Propagation  --
Nominal Delay  --
Nom. Conductor DC Resistance @ 20°C 4.43 Ohms/1000 ft
Nom. Outer Shield DC Resistance @ 20°C 2.7 Ohms/1000 ft
Max. Operating Voltage - UL 300 V RMS
Max. Recommended Current 5.1 Amps per conductor @ 25°C
NOTES: For use in indoor plenum environments but also suitable for outdoor and underground applications.

PUT-UPS AND COLORS - ALL SPOOLS ARE CONTINUOUS LENGTHS
89416 Cable
$950/1000 ft.
Put-Up (ft.) Ship Weight Jacket Color
89416 Cable 1000 45 lbs. RED
89416 Cable 2000 90 lbs. RED
89416 Cable 2500 112 lbs. RED
89416 Cable 3000 135 lbs. RED

PlenumCable2.com is a division of WorldWideWire.com.

Home Page

PHONE: (760) 832-1798 - FAX: (760) 328-9830
www.plenumcable2.com